Storage Performance Benchmarking with FIO

Flexible IO tester (FIO) is an open-source synthetic benchmark tool first developed by Jens Axboe.  FIO can generate various IO workloads: sequential reads or random writes, synchronous or asynchronous, all based on the options provided by the user.  FIO provides various global options through which different type of workloads can be generated.  FIO is the easiest and versatile tool to quickly perform IO performance tests on storage system, and allows you to simulate different types of IO loads and tweak several parameters, among others, the write/read mix and the amount of processes.  I’ll likely make a few additional posts with some of the other storage benchmarking tools I’ve used, but I’m focusing on FIO for this post.  Why FIO?  It’s a great tool, and it’s pros outweigh it’s cons for me.

Pros

  • It has a batch mode and a very extensive set of parameters.
  • Unlike IOMeter, it is still being actively developed.
  • It has multi-OS support.
  • It’s free.

Cons

  • It is CLI only, there are no GUI or Graphics features.
  • It has a rather complex syntax and it takes some time to get the hang of it.

Download and Installation

FIO can be run from either Linux or Windows, although Windows will first require an installation of Cygwin.  FIO works on Linux, Solaris, AIX, HP-UX, OSX, NetBSD, OpenBSD, Windows, FreeBSD, and DragonFly.  Some features and options may only be available on some of the platforms, typically because those features only apply to that platform (like the solarisaio engine, or the splice engine on Linux).  Note that you can check github for the latest version before you get started.

You can run the following commands from a Linux server to download and install the FIO package:

cd /root

yum install -y make gcc libaio-devel || ( apt-get update && apt-get install -y make gcc libaio-dev  </dev/null )

wget https://github.com/Crowd9/Benchmark/raw/master/fio-2.0.9.tar.gz ; tar xf fio*

cd fio*

make

How to compile FIO on 64-bit Windows:

Install Cygwin (http://www.cygwin.com/). Install **make** and all     packages starting with **mingw64-i686** and **mingw64-x86_64**.

Open the Cygwin Terminal.

Go to the fio directory (source files).

Run ``make clean && make -j``.

To build fio on 32-bit Windows, run ``./configure --build-32bit-win`` before ``make``.

FIO Cheat sheet

With FIO compiled, we can now run some tests.  For reference, I’ll start off with some basic commands for simulating different types of workloads.

Sequential Reads – Async mode – 8K block size – Direct IO – 100% Reads

fio --name=seqread --rw=read --direct=1 --ioengine=libaio --bs=8k --numjobs=8 --size=1G --runtime=600  --group_reporting

Sequential Writes – Async mode – 32K block size – Direct IO – 100% Writes

fio --name=seqwrite --rw=write --direct=1 --ioengine=libaio --bs=32k --numjobs=4 --size=2G --runtime=600 --group_reporting

Random Reads – Async mode – 8K block size – Direct IO – 100% Reads

fio --name=randread --rw=randread --direct=1 --ioengine=libaio --bs=8k --numjobs=16 --size=1G --runtime=600 --group_reporting

Random Writes – Async mode – 64K block size – Direct IO – 100% Writes

fio --name=randwrite --rw=randwrite --direct=1 --ioengine=libaio --bs=64k --numjobs=8 --size=512m --runtime=600 --group_reporting

Random Read/Writes – Async mode – 16K block size – Direct IO – 90% Reads/10% Writes

fio --name=randrw --rw=randrw --direct=1 --ioengine=libaio --bs=16k --numjobs=8 --rwmixread=90 --size=1G --runtime=600 --group_reporting

Host Considerations

To avoid IOs reporting out of the host system cache, use the direct option which will directly read/write to the disk.  Use the Linux native asynchronous IO using the ioengine directive with libaio.  When FIO is launched, it will create the file with the name provided in –name to the size as provided in –size with block size as –bs.  If the –numjobs are provided, it will create the files in the format of name.n.0 where n will be between 0 and –numjobs.

–jobs = The more jobs, the higher the performance can be, based on the resource availability.  If your server is limited on the resources (TCP or FC), I’d recommend running FIO across multiple servers to push a higher workload to the storage array.

Block Size Matters

Many storage vendors will advertise performance benchmarks based on 4k block sizes, which can artificially inflate the total IO number that the array is capable of handling.  In my professional experience with the workloads I’ve supported, the most popular read size is between 32KB and 64KB and the most popular write size is between 8KB and 32KB.  VMWare-heavy environments may skew a bit lower in read block size.  Read IO is typically more common than Write IO, at a rate of around 3:1.  It’s important to know the characteristics of your workload before you begin testing, as we need to look at IO Size as a weight attached to the IO. An IO of size 64KB will have a weight 8 times higher than an IO of size 8KB since it will move 8 times as many bytes.  A 256K block has 64 times the payload of a 4K block.  Both examples take substantially more effort for every component of the storage stack to satisfy the IO request. Applications and the operating systems they run on generate a wide, ever-changing mix of block sizes based on the characteristics of the application and the workloads being serviced. Reads and writes are often delivered using different block sizes as well. Block size has a significant impact on the latency your applications see.

Try to understand the IO size distributions of your workload and use those IO size modalities when you develop your FIO test commands. If a single IO size is a requirement for a quick rule-of-thumb comparison, then 32KB has been a pretty reasonable number for me to use, as it is a logical convergence of the weighted IO size distribution of most of the shared workload arrays I’ve supported. Your mileage may vary, of course.

Because block sizes have different effects on different storage systems, visibility into this metric is critical. The storage fabric, the protocol, the processing overhead on the HBAs, the switches, the storage controllers, and the storage media are all affected by it.

General Tips on Testing

Work on large datasets.  Your dataset should be at least double the amount of RAM in the OS.  For example, if the OS RAM is 16GB, test 32GB datasets multiplied by the number of CPU cores.

The Rule of Thumb:  75/25.  Although it really depends on your workloads, typically the rule of thumb is that there are 25% writes and 75% reads on the dataset.

Test from small to large blocks of I/O.  Consider testing small blocks of I/O up to large blocks of I/O in the following order: 512 bytes, 4K, 16K, 64K, 1MB to get proper measurement that can be the visualized as a histogram. This makes it easier to interpret.

Test multiple workload patterns.  Not everything is sequential read/write. Test all scenarios: read / write, write only, read only, random read / random write, random read only, and random write only.

Sample Output

Here’s a sample command string for FIO that includes many of the command switches you’ll want to use.  Each parameter can be tweaked to your specific environment.  It creates 8 files (numjobs=8) each with size 512MB (size) at 64K block size (bs=64k) and will perform random read/write (rw=randrw) with the mixed workload of 70% reads and 30% writes. The job will run for full 5 minutes (runtime=300 & time_based) even if the files were created and read/written.

[root@server1 fio]# fio --name=randrw --ioengine=libaio --iodepth=1 --rw=randrw --bs=64k --direct=1 --size=512m --numjobs=8 --runtime=300 --group_reporting --time_based --rwmixread=70

Output:

 Starting 8 processes

 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 randrw: Laying out IO file(s) (1 file(s) / 512MB)
 Jobs: 8 (f=8): [mmmmmmmm] [2.0% done] [252.0MB/121.3MB/0KB /s] [4032/1940/0 iops] [eta 04m:55s]
randrw: (groupid=0, jobs=8): err= 0: pid=31900: Mon Jun 13 01:01:08 2016
 read : io=78815MB, bw=269020KB/s, iops=4203, runt=300002msec
 slat (usec): min=6, max=173, avg= 9.99, stdev= 3.63
 clat (usec): min=430, max=23909, avg=1023.31, stdev=273.66
 lat (usec): min=447, max=23917, avg=1033.46, stdev=273.78
 clat percentiles (usec):
 | 1.00th=[ 684], 5.00th=[ 796], 10.00th=[ 836], 20.00th=[ 892],
 | 30.00th=[ 932], 40.00th=[ 964], 50.00th=[ 996], 60.00th=[ 1032],
 | 70.00th=[ 1080], 80.00th=[ 1128], 90.00th=[ 1208], 95.00th=[ 1288],
 | 99.00th=[ 1560], 99.50th=[ 2256], 99.90th=[ 3184], 99.95th=[ 3408],
 | 99.99th=[13888]
 bw (KB /s): min=28288, max=39217, per=12.49%, avg=33596.69, stdev=1709.09
 write: io=33899MB, bw=115709KB/s, iops=1807, runt=300002msec
 slat (usec): min=7, max=140, avg=11.42, stdev= 3.96
 clat (usec): min=1246, max=24744, avg=2004.11, stdev=333.23
 lat (usec): min=1256, max=24753, avg=2015.69, stdev=333.36
 clat percentiles (usec):
 | 1.00th=[ 1576], 5.00th=[ 1688], 10.00th=[ 1752], 20.00th=[ 1816],
 | 30.00th=[ 1880], 40.00th=[ 1928], 50.00th=[ 1976], 60.00th=[ 2040],
 | 70.00th=[ 2096], 80.00th=[ 2160], 90.00th=[ 2256], 95.00th=[ 2352],
 | 99.00th=[ 2576], 99.50th=[ 2736], 99.90th=[ 4256], 99.95th=[ 4832],
 | 99.99th=[16768]
 bw (KB /s): min=11776, max=16896, per=12.53%, avg=14499.30, stdev=907.78
 lat (usec) : 500=0.01%, 750=1.61%, 1000=33.71%
 lat (msec) : 2=50.35%, 4=14.27%, 10=0.04%, 20=0.02%, 50=0.01%
 cpu : usr=0.46%, sys=1.60%, ctx=1804510, majf=0, minf=196
 IO depths : 1=100.0%, 2=0.0%, 4=0.0%, 8=0.0%, 16=0.0%, 32=0.0%, &gt;=64=0.0%
 submit : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, &gt;=64=0.0%
 complete : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, &gt;=64=0.0%
 issued : total=r=1261042/w=542389/d=0, short=r=0/w=0/d=0
 latency : target=0, window=0, percentile=100.00%, depth=1
Run status group 0 (all jobs):
 READ: io=78815MB, aggrb=269020KB/s, minb=269020KB/s, maxb=269020KB/s, mint=300002msec, maxt=300002msec
 WRITE: io=33899MB, aggrb=115708KB/s, minb=115708KB/s, maxb=115708KB/s, mint=300002msec, maxt=300002msec

Additional Samples

I’ll run through an additional set of simple examples of using FIO as well using different workload patterns.

Random read/write performance

If you want to compare disk performance with a simple 3:1 4K read/write test, use the following command:

./fio --randrepeat=1 --ioengine=libaio --direct=1 --gtod_reduce=1 --name=test --filename=test --bs=4k --iodepth=64 --size=4G --readwrite=randrw --rwmixread=75

This command string create a 4 GB file and perform 4KB reads and writes using a 75%/25% split within the file, with 64 operations running at a time. The 3:1 ratio represents a typical database.

The output is below, with the IO numbers highlighted in red.

Jobs: 1 (f=1): [m] [100.0% done] [43496K/14671K /s] [10.9K/3667 iops] [eta 00m:00s]
test: (groupid=0, jobs=1): err= 0: pid=31214: Fri May 9 16:01:53 2014
read : io=3071.1MB, bw=39492KB/s, iops=8993 , runt= 79653msec
write: io=1024.7MB, bw=13165KB/s, iops=2394 , runt= 79653msec
cpu : usr=16.26%, sys=71.94%, ctx=25916, majf=0, minf=25
IO depths : 1=0.1%, 2=0.1%, 4=0.1%, 8=0.1%, 16=0.1%, 32=0.1%, >=64=100.0%
submit : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
complete : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.1%, >=64=0.0%
issued : total=r=786416/w=262160/d=0, short=r=0/w=0/d=0
Run status group 0 (all jobs):
READ: io=3071.1MB, aggrb=39492KB/s, minb=39492KB/s, maxb=39492KB/s, mint=79653msec, maxt=79653msec
WRITE: io=1024.7MB, aggrb=13165KB/s, minb=13165KB/s, maxb=13165KB/s, mint=79653msec, maxt=79653msec
Disk stats (read/write):
vda: ios=786003/262081, merge=0/22, ticks=3883392/667236, in_queue=4550412, util=99.97%

This tests shows the array performed 8993 read operations per second and 2394 write operations per second.

Random read performance

To measure random reads, we’ll change FIO command a bit:

./fio --randrepeat=1 --ioengine=libaio --direct=1 --gtod_reduce=1 --name=test --filename=test --bs=4k --iodepth=64 --size=4G --readwrite=randread

Output:

Jobs: 1 (f=1): [r] [100.0% done] [62135K/0K /s] [15.6K/0 iops] [eta 00m:00s]
test: (groupid=0, jobs=1): err= 0: pid=31181: Fri May 9 15:38:57 2014
read : io=1024.0MB, bw=62748KB/s, iops=19932 , runt= 16711msec
cpu : usr=5.94%, sys=90.13%, ctx=1885, majf=0, minf=89
IO depths : 1=0.1%, 2=0.1%, 4=0.1%, 8=0.1%, 16=0.1%, 32=0.1%, >=64=100.0%
submit : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
complete : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.1%, >=64=0.0%
issued : total=r=262144/w=0/d=0, short=r=0/w=0/d=0
Run status group 0 (all jobs):
READ: io=1024.0MB, aggrb=62747KB/s, minb=62747KB/s, maxb=62747KB/s, mint=16711msec, maxt=16711msec
Disk stats (read/write):
vda: ios=259063/2, merge=0/1, ticks=951356/20, in_queue=951308, util=96.83%

This test shows the storage array performing 19,932 read operations per second.

Random write performance

Modify the FIO command slightly to use randwrite instead of randread for the random write test.

./fio --randrepeat=1 --ioengine=libaio --direct=1 --gtod_reduce=1 --name=test --filename=test --bs=4k --iodepth=64 --size=4G --readwrite=randwrite

Output:

Jobs: 1 (f=1): [w] [100.0% done] [0K/26326K /s] [0 /6581 iops] [eta 00m:00s]
test: (groupid=0, jobs=1): err= 0: pid=31235: Fri May 9 16:16:21 2014
write: io=1024.0MB, bw=29195KB/s, iops=5434, runt= 35916msec
cpu : usr=77.42%, sys=13.74%, ctx=2306, majf=0, minf=24
IO depths : 1=0.1%, 2=0.1%, 4=0.1%, 8=0.1%, 16=0.1%, 32=0.1%, >=64=100.0%
submit : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.0%
complete : 0=0.0%, 4=100.0%, 8=0.0%, 16=0.0%, 32=0.0%, 64=0.0%, >=64=0.1%
issued : total=r=0/w=262144/d=0, short=r=0/w=0/d=0
Run status group 0 (all jobs):
WRITE: io=1024.0MB, aggrb=29195KB/s, minb=29195KB/s, maxb=29195KB/s, mint=35916msec, maxt=35916msec
Disk stats (read/write):
vda: ios=0/260938, merge=0/11, ticks=0/2315104, in_queue=2316372, util=98.87%

This tests shows storage scoring 5,434 write operations per second.

Advertisements

Storage Performance Metrics

I often get requests from application owners to review storage performance stats.  I thought I’d give a quick overview of some of the things I look at, what the myriad of performance metrics in commonly used storage performance software tools actually mean, and how you might use some of them to investigate a performance problem.  Performance analysis is very much an art (not a science) and it’s sometimes difficult to pinpoint exact causes based on the mix of applications and workload on the array. Taking all of the metrics into account with a holistic view is needed to be successful. Performing data collection of application workloads over time is recommended because application workload characteristics will likely vary over time. If you have a major problem, I would always recommend opening a service ticket with your hardware vendor.

This post is just an overview of storage performance metrics and isn’t meant to dive in to every possible scenario from every angle. Dell EMC has some excellent guides for performance best practices that you can read here:

Ive used a variety of software tools in my tenure as a storage administrator.  EMC’s Performance Manager, Windows PerfMon, NetApp OnCommand Insight, Solar Winds SRM, ViPR SRM, and of course the ubiquitous Navisphere Analyzer.  All of them basically use the same metrics, so the following information will be useful regardless of which method you use.

The first thing I do when reviewing a potential storage array performance problem is a quick look at the Storage Processors.  This will give you a good indication of the overall health of the array before you dive into the specific LUN (or LUNs) used by the application.

  • SP Cache Dirty Pages (%). These are pages in write cache that have received new data from hosts but have not yet been flushed to disk.  You should have a high percentage of dirty pages as it increases the chance of a read coming from cache or additional writes to the same block of data being absorbed by the cache. If an IO is served from cache the performance is better than if the data had to be retrieved from disk.  That’s why the default watermarks are usually around 60/80% or 70/90%.  You don’t want dirty pages to reach 100%, they should fluctuate between the high and low watermarks (which means the Cache is healthy).  Periodic spikes or drops outside the watermarks are ok, but consistently hitting 100% indicates that the write cache is overstressed.
  • SP Utilization (%). Check and see if either SP is running higher than about 75%.  If either is running that high application response time will be increased.  Also, both will need to be under 50% for non-disruptive upgrades. We had to do a large scale migration of data from one SAN to another at one point in order to get a NDU accomplished.  You’ll also want to check for proper balance.  If one is much higher than the other, you should consider migrating LUNs from one SP owner to another.  I check SP balance on all of our arrays on a daily basis.
  • SP Response time (ms). Make sure again that both SPs are even and that response time is acceptable. I like to see response times under 10ms.  If you see that one SP has high utilization and response time but the other SP doesn’t, look for LUNs owned by the busier SP that are using more array resources. Looking at total IO on a per LUN basis can help confirm If both SPs have relatively similar throughput but one SP has much higher bandwidth.  That could mean that there is some large block IO occurring.
  • SP Port Queue Full Count. This represents the number of times that a front end port issued a QFULL response back to the hosts. If you are seeing QFULL’s it could mean that the Queue Depth on the HBA is too large for the LUNs being accessed.  A Clariion/VNX front end port has a queue depth of 1600 which is the maximum number of simultaneous IO’s that port can process.  Each LUN on the array has a maximum queue depth that is calculated using a formula based on the number of data disks in the RAID Group. For example, a port with 512 queues and a typical LUN queue depth of 32 can support up to: 512 / 32 = 16 LUNs on 1 Initiator (HBA) or 16 Initiators (HBAs) with 1 LUN each or any combination not to exceed this number. Configurations that exceed this number are in danger of returning QFULL conditions. A QFULL condition signals that the target/storage port is unable to process more IO requests and thus the initiator will need to throttle IO to the storage port. As a result of this, application response times will increase and IO activity will decrease.

The next thing I do is look at the specific LUNs that the application owner is asking about. The list below includes the basic performance metrics that I most often look at when investigating a performance problem.

  • Utilization (%) represents the fraction of an observation period during which a LUN has any outstanding requests. When the LUN becomes the bottleneck, the utilization will be at or close to 100%. However, since I/Os can get serviced by multiple disks an increase in workload might still result in a higher throughput.  Utilization by itself is not a very good indicator of the overall performance of the LUN, it needs to be factored in with several other things. For example, If you are writing to a LUN (100% Writes) and the location of the data is in a small physical space on the LUN, it may be possible to get to 100% with write cache re-hits. This means that all writes are being serviced by the write cache and since you are writing data to the same locations over and over you do not flush any of the data to the disks. This can cause your LUN Utilization to be 100% but there will actually be no IO to the disks. Utilization is very affected by caching, both read and write. The LUN can be very busy but may not have a problem. Use Utilization to assist in identifing busy LUNs then look at queuing and response times to see if there really is an issue.
  • Queue Length is the average number of requests within a polling interval that are outstanding to this LUN. A queue length of zero indicates an idle LUN. If three requests arrive at an idle LUN at the same time, only one of them can be served immediately; the other two must wait in the queue. That scenario would result in a queue length of 3.  My general guideline for “bad performance” on a LUN is a queue length greater than 2 for a single disk drive.
  • Average Busy Queue Length is the average number of outstanding requests when the LUN was busy. This does not include any idle time. This value should not exceed 2 times the number of spindles on a LUN. For example, if a LUN has 25 spindles, a value of 50 is acceptable. Since this queue length is counted only when the LUN is not idle, the value indicates the frequency variation (burst frequency) of incoming requests. The higher the value, the bigger the burst and the longer the average response time at this component. In contrast to this metric, the average queue length does also include idle periods when no requests are pending. If you have 50% of the time just one outstanding request, and the other 50% the LUN is idle, the average busy queue length will be 1. The average queue length however, will be ½.
  • Response Time (ms) is the average time, in milliseconds, that a request to this LUN is outstanding, including its waiting time. The higher the queue length for a LUN, the more requests are waiting in its queue, thus increasing the average response time of a single request. For a given workload, queue length and response time are directly proportional.  Keep in mind that cache re-hits bring down the average response time (and service times), whether they are reads or writes. LUN Response time is a good starting point for troubleshooting. It gives a good indicator of what the host system is experiencing. Usually if your LUN response time (Response time = queue length * service time) is good then the host performance is good. High response times don’t always mean that the CLARiiON is busy, it can also indicate that you’re having issues with your host or Fabric.  We use the Brocade Health report on a regular basis to identify hosts that have an excessive amount of traffic, as well as running the EMC HEAT report on hosts that have reported issues (which can identify incorrect HBA Drivers, Bad HBA, etc).These are my general guidelines for response time:
    Less than 10 ms: very good
    Between 10 – 20 ms: okay
    Between 20 – 50 ms: slow, needs attention
    Greater than 50 ms:  I/O bottleneck
  • Service Time (ms) represents the Time, in milliseconds, a request spent being serviced by a component. It does not include time waiting in a queue. Service time is mainly a characteristic of the system component. However, larger I/Os take longer and therefore usually result in lower throughput (IO/s) but better bandwidth (Mbytes/s). In general, Service time is simply the time it takes to actually send the I/O request to the storage and get an answer back. In general, I like to see service times below 20ms.
  • Total Throughput (IO/sec) is the average number of host requests that is passed through the LUN per second. This includes both read and write requests. Smaller requests usually result in a higher total throughput than larger requests.  Examining total throughput (along with %Utilization) is a good way to identify the busiest LUNs on the array. In general, here are the IOPs limits by drive type:
RPM        Drive Type      IOPs
7,200      SATA,NL-SAS     ~80
10,000     SATA,NL-SAS     ~130
10,000     FC,SAS          ~140
15,000     FC,SAS          ~180
N/A        EFD             ~1500 (Read/Write, 60/40)
N/A        EFD             ~6000 (Read)
N/A        EFD             ~3000 (Write)
  • Write Throughput (I/O/sec) The average number of host write requests that is passed through the LUN per second. Smaller requests usually result in a higher write throughput than larger requests.  When troubleshooting specific LUNs, check the write IO size and see if the size is what you would expect for the application you are investigating. Extremely large IO sizes coupled with high IOPS may cause write cache contention.
  • Read Throughput (I/O/sec) The average number of host read requests that is passed through the LUN per second. Smaller requests usually result in a higher read throughput than larger requests.
  • Total Bandwidth (MB/s) The average amount of host data in Mbytes that is passed through the LUN per second. This includes both read and write requests. Larger requests usually result in a higher total bandwidth than smaller requests.
  • Read Bandwidth (MB/s) The average amount of host read data in Mbytes that is passed through the LUN per second. Larger requests usually result in a higher bandwidth than smaller requests.
  • Write Bandwidth (MB/s) The average amount of host write data in Mbytes that is passed through the LUN per second. Larger requests usually result in a higher bandwidth than smaller requests. Keep in mind that writes consume many more array resources than reads.
  • Read Size (KB) The average read request size in Kbytes seen by the LUN. This number indicates whether the overall read workload is oriented more toward throughput (I/Os per second) or bandwidth (Mbytes/second). For a finer distinction of I/O sizes, use an IO Size Distribution chart for this LUN.
  • Write Size (KB) The average write request size in Kbytes seen by the LUN. This number indicates whether the overall write workload is oriented more toward throughput (I/Os per second) or bandwidth (Mbytes/second). For a finer distinction of I/O sizes, use an IO Size Distribution chart for the LUNs.

Below is an explanation of additional performance metrics that I don’t use as frequently, but I’m including them for completeness.

  • Forced Flushes/s Number of times per second the cache had to flush pages to disk to free up space for incoming write requests. Forced flushes are a measure of how often write requests will have to wait for disk I/O rather than be satisfied by an empty slot in the write cache. In most well performing systems this should be zero most of the time. 
  • Full Stripe Writes/s Average number of write requests per second that spanned a whole stripe (all disks in a LUN). This metric is applicable only to LUNs that are part of a RAID5 or RAID3 group.
  • Used Prefetches (%) The percentage of prefetched data in the read cache that was read during the last polling interval.
  • Disk Crossing (%) Percentage of host requests that require I/O to at least two disks compared to the total number of host requests. A single disk crossing can involve more than two disk drives.
  • Disk Crossings/s Number of times per second that a request requires access to at least two disk drives. A single disk crossing can involve more than two disks.
  • Read Cache Hits/s Average number of read requests per second that were satisfied by either read or write cache without requiring any disk access. A read cache hit occurs when recently accessed data is re-referenced while it is still in the cache.
  • Read Cache Misses/s Average number of read requests per second that did require one or more disk accesses.
  • Reads From Write Cache/s Average number of read requests per second that were satisfied by write cache only. Reads from write cache occur when recently written data is read again while it is still in the write cache. This is a subset of read cache hits which includes requests satisfied by either the write or the read cache.
  • Reads From Read Cache/s Average number of read requests per second that were satisfied by the read cache only. Reads from read cache occur when data that has been recently read or prefetched is re-read while it is still in the read cache. This is a subset of read cache hits which includes requests satisfied by either the write or the read cache.
  • Read Cache Hit Ratio The fraction of read requests served from both read and write caches vs. the total number of read requests. A higher ratio indicates better read performance.
  • Write Cache Hits/s Average number of write requests per second that were satisfied by the write cache without  requiring any disk access. Write requests that are not write cache hits are referred to as write cache misses.
  • Write Cache Misses/s Average number of write requests per second that did require one or multiple disk accesses. Write requests that cause forced flushes or that bypass the write cache due to their size are examples of write cache misses.
  • Write Cache Rehits/s Average number of write requests per second that were satisfied by the write cache since they had been referenced before and not yet flushed to the disks. Write cache rehits occur when recently accessed data is referenced again while it is still in the write cache. This is a subset of Write Cache Hits.
  • Write Cache Hit Ratio The ratio of write requests that the write cache satisfied without requiring any disk access vs. the total number of write requests to this LUN. A higher ratio indicates better write performance.
  • Write Cache Rehit Ratio The ratio of write requests that the write cache satisfied since they have been referenced before and not yet flushed to the disks vs. the total number of write requests to this LUN. This is a measure of how often the write cache succeeded in eliminating a write operation to disk. While improving the rehit ratio is useful it is more beneficial to reduce the number of forced flushes.